Updated Oct 17, 2024
Suprema's Visual Face devices cannot be added as RS-485 Slave devices alongside Fingerprint, Face (e.g., FaceStation 2 or FaceLite), or Card devices. Additionally, there may be restrictions on [RS-485 Master - Slave] connections between Visual Face devices depending on the configuration.
If you are considering the installation of Visual Face products for your project, please refer to the list below to ensure that your wiring and installation are perfectly set up.
CANNOT USE
- Any of Fingerprint device (Master) - FaceStation F2 / BioStation 3 / BioEntry W3 (Slave)
- Any of Card device (Master) - FaceStation F2 / BioStation 3 / BioEntry W3 (Slave)
- Any of 1st generation device* (Master) - FaceStation F2 / BioStation 3 / BioEntry W3 (Slave)
- FaceStation 2 or FaceLite (Master) - FaceStation F2 / BioStation 3 / BioEntry W3 (Slave)
- FaceStation F2 (Master) - BioStation 3 (Slave)
- FaceStaiton F2 (Master) - BioEntry W3 (Slave)
- BioStation 3 (Master) - FaceStation F2 (Slave)
- BioEntry W3 (Master) - FaceStation F2 (Slave)
CAN USE
- FaceStation F2 (Master) - FaceStation F2 (Slave)
- BioStation 3 (Master) - BioStation 3 (Slave)
- BioStation 3 (Master) - BioEntry W3 (Slave)
- BioEntry W3 (Master) - BioStation 3 (Slave)
- BioEntry W3 (Master) - BioEntry W3 (Slave)
* What is 1st generation device?
** Suprema Visual Face devices
- FaceStation F2, BioStation 3, BioEntry W3
FaceStation F2 | BioStation 3 | BioEntry W3 |
[BioStar 2] New Product Introduction - FaceStation F2 | [BioStar 2] New Product Introduction - BioStation 3 | [BioStar 2] New Product Introduction - BioEntry W3 |