Dear Valued Partners, 


Suprema team is going to announce the firmware release information every month. 


Below is the updated firmware information in January.


Applied to

BioEntry P2, Secure IO2, OM-120, and BioStation 2

 

 

Product NameProduct
Image
Firmware
Version
Updated informationRelease Date
BioEntry P2v1_4_3_202112131. Bug Fixes
1.1. The card ID was always output as MSB through OSDP when the card ID was input while the device was connected by an intelligent slave (Affects version: v1.4.1).
1.2. The user ID was abnormally displayed in the event log if the user authenticated with AoC set as the blacklist card when the User ID Type was set to Alphanumeric (Affects version: v1.0.0).
1.3. The device failed to recognize the iCLASS Seos card intermittently before rebooting the device (BEP2-OA) (Affects version: v1.0.0).
1.4. When the device is connected as an intelligent slave and the first card registered to the user is a Wiegand card of a format other than 26-bit, the CSN value is output through OSDP when authenticated with the user's fingerprint (Affects version: v1.4.1).
 1.5. The fingerprint sensor was deactivated after upgrading the firmware to v1.4.2 and it was reactivated only when the device is restarted (Affects version: v1.4.2).
1/26/2022
X-Station 2v1.1.2_2112201. New features and improvement
1.1. Improved QR/Barcode reading performance.
1.2. Improved the speed at which the device recognizes objects.
 1.3. Supports LCDs from multiple manufacturers.
1/28/2022
2. Bug Fixes
2.1. The device rebooted abnormally when a user scanned a card on the device with several cards overlapped in a wallet or the like (Affects version: v1.0.0).
2.2. When setting the elevator to the scheduled unlock zone and using the 'Started by User Authentication' option, the floor is activated normally when a user belonging to the access group authenticates, but the 'Floor released' logs are output (Affects version: v1.0.0).
2.3. Improved to check for the duplication of cards registered with users when transmitting user data from the server to devices (Affects version: v1.0.0).
2.4. The master device reboots if re-searching the slave device while RS-485 communication is operating normally (Affects version: v1.0.0).
2.5. String resources were not updated when upgrading firmware (Affects version: v1.0.0).
2.6. PIN authentication did not work properly when using Device Hashkey Management (Affects version: v1.0.0).
2.7. When loading the logs for the user who entered the admin menu using the SDK, the user ID was not displayed (Affects version: v1.0.0).
2.8. The device failed to recognize the iCLASS Seos card suddenly (XS2-APB, XS2-QAPB, XS2-OAPB) (Affects version: v1.0.0).
2.9. When authenticating on a device that has dual authentication set up, the authentication success sound is not output for the dual authentication result, and the home screen is maintained (Affects version: v1.0.0).
2.10. Slave devices are disconnected when the master device is rebooted (Affects version: v1.0.0).
2.11. Even though the device's language was set to Korean, some phrases were displayed on the screen in English (Affects version: v1.0.0).
2.12. The device reboots abnormally when the user authenticates the card continuously (Affects version: v1.0.0).
2.13. The 'Delete the Root Certificate' was not displayed when a user with the administrator level accessed the menu on the device where the certificate was stored (Affects version: v1.0.0).
 2.14. When initializing the master device with the 'Without Network' option, the RS-485 communication key was initialized and the slave device was disconnected (Affects version: v1.0.0).
BioStation 2v1.10.1_2111231. Bug Fixes
1.1. When setting the elevator to the scheduled unlock zone and using the 'Started by User Authentication' option, the floor is activated normally when a user belonging to the access group authenticates, but the 'Floor released' logs are output (Affects version: v1.2.0).
1.2. Improved to check for the duplication of cards registered with users when transmitting user data from the server to devices (Affects version: v1.8.0).
1.3. If some ports of the OM-120 connected as a slave are set as a door relay and the device is rebooted, the relay was operated abnormally (Affects version: v1.0.0).
1.4. When loading the logs for the user who entered the admin menu using the SDK, the user ID was not displayed (Affects version: v1.0.0).
1.5. The device failed to recognize the iCLASS Seos card intermittently before rebooting the device (BS2-OIPW) (Affects version: v1.0.0).
1.6. The 'Delete the Root Certificate' was not displayed when a user with the administrator level accessed the menu on the device where the certificate was stored (Affects version: v1.9.0).
1.7. When authenticating on a device that has dual authentication set up, the authentication success sound is not output for the dual authentication result, and the home screen is maintained (Affects version: v1.10.0).
1.8. Slave devices are disconnected when the master device is rebooted (Affects version: v1.0.0).
1.9. The user ID was abnormally displayed in the event log if the user authenticated with AoC set as the blacklist card when the User ID Type was set to Alphanumeric (Affects version: v1.0.0).
1.10. Abnormal authentication failure occurred when the slave device's auth mode was set to card+fingerprint (Affects version: v1.9.0).
1.11. PIN authentication did not properly work when using Device Hashkey Management (Affects version: v1.9.0).
 1.12. When initializing the master device with the 'Without Network' option, the RS-485 communication key was initialized and the slave device was disconnected (Affects version: v1.0.0).
1/28/2022
Secure IO2v1_3_1_202201031. New Features and Improvements
1.1. Improvements related to RS-485 communication.
2. Bug Fixes
 2.1. Device ID value changed to 0 abnormally (Affects version: v1.0.0).
1/27/2022
OM-120v1.2.1_2201031. New Features and Improvements
1.1. Improvements related to RS-485 communication.
2. Bug Fixes
 2.1. The door relay did not operate according to the input status due to a relay 6-11 port order error (Affects version: v1.0.0).
1/27/2022


You can download the firmware file to each device download page from the Suprema website. 