Affected Products & Versions
All device contains both card and fingerprint scanners(P2, W2, L2, A2, BS2, N2) current FW (30 August 2019)
Summary
When the device is set as Wiegand out in BioStar 2, it sends the wrong number through the Wiegand out when authenticating with fingerprint after card scanning from BioStar 2.
The Wiegand device stores a scanned card value, and send out through the Wiegand out incorrectly when fingerprint authentication.
- This issue happens to device that is configured as a Wiegand output
- Due to the 2nd sequence, it does not occur when Suprema device is used as a Wiegand reader in third-party ACM (card scan command cannot be executed)
Reproduction process
1. 'Scan card' command for card registration (not authentication)
2. Fingerprint authentication (card authentication does not cause issues)
Cause
Bug
Solution
Upgrade to the beta FW. All beta FW is included at the link below.
FISF_1182 - http://gofile.me/471Oh/U8SXVzOiw
Some FW is not uploaded yet. Please create a ticket if you need a beta for other devices urgently.