Dear Valued Partners,
This is an announcement of our new firmware releases from Jul 16, 2024 - Aug 15, 2024.
You can click the link to download each device's firmware and revision notes.
1. Released Models
- FaceStation F2, BioStation 2, BioLite N2
2. Details
Product Model | FaceStation F2 | Release Version | v2.2.0 (Download) |
Revision Note | FaceStation F2 Revision Notes v2.2.0 |
<New Features and Improvements> - Supports Custom Smart Card Layout.
- Added Store Visual Face Image feature.
- Supports the feature to save both the actual image and the template in the visual face, or to save only the template without storing the actual image.
- Supports Template on Mobile.
- XPass D2 new BLE (Bluetooth Low Energy) chip firmware (Build No. 1.7.0_220921) support.
- The BLE chip parts of the hardware have been changed, and the firmware has been upgraded to be compatible with both the existing and new BLE chips.
- Improved smartcard output byte order setting.
- When using Wiegand or OSDP output, it is improved to be affected by the smartcard output byte order when the Wiegand output information is set to send user ID.
- Extended the user expiration period to a maximum of '2037-12-31'.
- Supports the Display Result from Controller feature for displaying authentication success or failure results from a 3rd party controller on the device screen when using Intelligent Slave.
- Supports the Ignore Repeated Signals Duration feature, which ignores repetitive authentication signals from the controller when the device is connected to a 3rd party controller via Wiegand.
- Improved duplicate fingerprint detection.
- Improved to get user update succeeded event log using the GetLogWithFilter function in the SDK.
- Supports the Auth Result Display Option that allows you to select how the user ID and name are displayed on the authentication result screen of the device.
- Improved to ensure that values set with osdp_comset are correctly applied on the device connected as a slave.
|
Product Model | BioStation 2 | Release Version | v1.10.2 (Download) |
Revision Note | No link is available. Please find details below. |
NOTICE BioStation 2 is the product that Suprema has announced the discontinuance of already. If you want to check the EoL schedule, please find it in the link below.
<New Features and Improvements> - Improved to ensure that values set with osdp_comset are correctly applied on the device connected as a slave.
- Improved to get user update succeeded event log using the GetLogWithFilter function in the SDK.
<Bug Fixes> - Migration malfunction occurs when the firmware is upgraded from v1.6.1 to v1.10.1. (Affects version: v1.9.0)
- Migration did not complete and the device boots to the main screen, some keys do not work or an abnormal screen is displayed.
- Device does not recognize certain HID iCLASS Seos cards. (Affects version: v1.0.0)
- The user ID stored as a 32-character string is truncated to only 31 characters in a specific event log. (Affects version: v1.0.0)
- Intermittently, the door does not open even if authentication succeeds when the door uses the slave device’s relay. (Affects version: v1.0.0)
- When a user with a 32-character user ID authenticates to the device while the device is not connected to the server, the authentication event log is not updated in BioStar 2 even after the device is reconnected to the server. (Affects version: v1.0.0)
- When a device is connected to Wireless, turning off the power to the wireless AP, restarting the device, and then turning the wireless AP back on causes Wireless to not automatically reconnect. (Affects version: v1.0.0)
|
Product Model | BioLite N2 | Release Version | v1.6.1 (Download) * Will be updated soon. |
Revision Note | BioLite N2 Revision Notes v1.6.1(* Will be updated soon.) |
<New Features and Improvements> - XPass D2 new BLE (Bluetooth Low Energy) chip firmware (Build No. 1.7.0_220921) support.
- The BLE chip parts of the hardware have been changed, and the firmware has been upgraded to be compatible with both the existing and new BLE chips.
- Improved synchronization to complete if user enrollment fails when synchronizing multiple users to the device in BioStar 2.
- Improved smartcard output byte order setting.
- When using Wiegand or OSDP output, it is improved to be affected by the smartcard output byte order when the Wiegand output information is set to send user ID.
- Improved to not recognize SEOS configuration cards as CSN for 1 minute after device booting.
- Improved to get user update succeeded event log using the GetLogWithFilter function in the SDK.
- Improved to ensure that values set with osdp_comset are correctly applied on the device connected as a slave.
|