Device

[Both BioStar] Information about Firmware Version Conversion (Xpass, Xpass S2, BioEntry Plus, BioEntry W, BioLiteNet)
Customer's Question - Can we upgrade version 1 firmware to version 2 firmware to use with BioStar2 SW? - Can we downgrade version 2 firmware to versio...
Thu, Nov 26, 2020 at 2:15 PM
[Both BioStar] Information about Firmware Convert (Xpass, Xpass S2, BioEntry Plus, BioEntry W, BioLiteNet)
Customer's Question - Can we upgrade version 1 device to version 2 device to use BioStar2 SW? - Can we downgrade version 1 device to version 1 device ...
Mon, Aug 3, 2020 at 9:15 AM
[BioStar 1] Uploading Users from Device to Server
Normally, you would backup and restore a database to restore your previous user database.  However, if there is a special circumstance where you have to up...
Thu, Jul 19, 2018 at 5:08 PM
[BioStar 1] Why 2nd Generation Devices Store 2 Cards When 1 CSN Card is Transferred
Why 2 Cards are Stored When a card is stored in a 2nd generation device, it has to be decided if the card will be a CSN or Wiegand card but in BioStar 1.x t...
Mon, Feb 1, 2021 at 4:41 PM
[Both BioStar] Entry Device Firmware (Xpass, Xpass S2, BioEntry Plus, BioEntry W, BioLiteNet)
The line of 1st generation entry level devices are as follows: Xpass, Xpass 2, BioEntry Plus, Bioentry W, BioLiteNet These devices (with the latest hardw...
Thu, Jul 19, 2018 at 4:03 PM
[BioStar 2] Supervised Input
The DM-20 and CoreStation can detect 4 states such as ON, OFF, Open, and Short Circuit by using the Supervised Input port. With the ‘Trigger and Action’ fun...
Mon, Jul 9, 2018 at 4:54 PM
[BioStar 2] Maximum Slave Devices with CoreStation
Maximum Devices Per Port CoreStation has 5 RS-485 ports and in total CoreStation supports maximum of 64 slave devices but each port supports up to 31 slave...
Thu, May 10, 2018 at 10:28 AM
[BioStar 1] Importing BioStation Device Logs with USB
This only applies to BioStation 1.  You can export the device logs from the device and then import it with BioStar by plugging in the USB in the BioStar...
Tue, May 8, 2018 at 3:35 PM
[BioStar 1] FaceStation 1 Template Size
Below are some answers regarding FaceStation 1 template sizes Is a video saved in the Database? FaceStation does not record any videos. Hence such info...
Wed, May 2, 2018 at 3:00 PM
[BioStar 2] Using 2nd Generation Devices with DDNS
2nd generation devices can work with DDNS in BioStar 2.  This does not work for BioLiteNet, BioEntry Plus, and BioEntry W, Xpass, Xpass S2 (blackfin/entry ...
Thu, Aug 9, 2018 at 8:01 AM