Known Issues

[Known Issue] BioStar 2 server is using too much CPU resources
Affected Products & Versions BioStar 2.7.7 ~ BioStar 2.7.10 Summary BioStar 2 server is using too much CPU resources in the task manager Cause Th...
Mon, Feb 1, 2021 at 4:26 PM
[Known Issue] BioEntry Plus 1.x Blinking Red LED Issue
Affected Products & Versions: all BioEntry Plus 1.x firmware Summary Without changing the device configuration (not in lock status) the BioEntry Pl...
Mon, Feb 1, 2021 at 4:24 PM
[Known Issue] RS485 slave device is disconnected or shown a different version
Affected Products & Versions Master CS40 V1.3.0, BEW2 V1.4.0, BSL2 V1.5.0, BEP2 V1.3.0, XP2 V1.0.1 Slave DM20 V1.1.2 or lower, OM120 V1.0.0  Summary...
Mon, Feb 1, 2021 at 3:46 PM
[Known Issue] Can't scan a fingerprint via BioMini/BioMini Plus 2 randomly - Solution
- Affected Products & Versions Biostar 1 & BioStar 2 - Summary Sometime, a user can't scan a fingerprint through BioMini/ BioMini Plus 2 ...
Mon, Jan 18, 2021 at 3:53 PM
[Known Issue] Slave device is not showing but it works after restart BioStar 2 web server
Affected Products & Versions: All versions (Current version : 2.8.8) Summary : BioStar 2 spring server doesn't work properly if the server ha...
Tue, Nov 10, 2020 at 4:40 PM
[Known Issue] License Check Appearing in BioStar 2 When License is Not Required
Affected Products & Versions All versions Summary During the BioStar 2 upgrade, the 'License check' process appears even though the serv...
Wed, Nov 4, 2020 at 8:49 AM
[Known Issue] Access denied even the user updated with valid access groups
Affected Products & Versions BioStar 2.7.8 or lower versions Summary Authentication failure message(Access denied-Invalid access group) after user ...
Wed, Nov 4, 2020 at 8:28 AM
[Known Issue] BioStar 1.93 DB Link Issue
Affected Products & Versions: BioStar 1.93 Summary If you are adding users through a DB link program in BioStar 1.93 you will notice that the right...
Thu, Sep 17, 2020 at 3:21 PM
[Known Issue] BioStar 2.4.1 MS SQL DB Connection Check Bug in the Installation Process and BioStar Setting
DB Connection Check Bug in the Installation Process and BioStar Setting   Affected Products & Versions: BioStar 2.4.1 (MS SQL for installation issue) ...
Thu, Sep 17, 2020 at 9:01 AM
[Known Issue] Xpass D2(MDB and Keypad both) doesn't support for LSB
Affected Products & Versions: Xpass D2 Keypad 1.1.0 or lower versions as RS485 slave Summary The input number pressed on XPass D2 Keypad shows t...
Wed, Jul 29, 2020 at 9:08 AM